If a hood is to be installed above the hob, refer to the hood installation instructions to ensure the correct
height above the hob
Note: If the distance “A” between the wall cupboards in the kitchen is between 600mm and 730mm, the
height “B” must be at least 530mm.
If the distance “A” between the wall cupboards is greater than the width of the hob, the height “B” must
be at least 400 mm.
Hood and cabinetry clearances (mm)
560
+2
- 0
490
+2
- 0
730
510
45
min. R 6,5
max R 16
63 min.
Category II2ELL3B/P (DE) II2H3B/P (AT)
Type of gas used Type of Injector Injector Nominal heat Nominal Reduced heat Gas pressure (mbar)
burner label distance (X) mm flow kW consumption flow kW min. nom. max
NATURAL GAS wok 145 6 4,20 400 l/h 1,55 17 20 25
(Methane) G20 semi-rapid 95 - 1,65 157 l/h 0,35
auxiliary 78 - 1,00 95 l/h 0,30
LIQUID wok 78 13,5 3,80 276 g/h 2,55 42,5 50 57,5
PETROLEUM GAS semi-rapid 60 - 1,65 120 g/h 0,45
(Butane-Propane) G30/G31 auxiliary 46 - 1,00 73 g/h 0,35
wok 160 6 4,2 465 l/h 1,55 18 20 25
NATURAL GAS semi-rapid 104 - 1,65 183 l/h 0,35
(Methane) *G25 auxiliary 82 - 1,00 111 l/h 0,30
Type of gas used Configuration Nominal heat Overall nominal Required air (m
3
)
model consumption kW consumption for the combustion 1 m
3
of gas
G20 20 mbar 4 burners 8,50 809 l/h 9,52
G30/G31 50 mbar 4 burners 8,10 589 g/h 30,94
*G25 20 mbar 4 burners 8,50 942 l/h 8,187
Electric Power: 230 V ~ 50 Hz
* Not applicable to Austria
Injectors table
6
181,6
274
22
16
Przeglądanie stron 5